Pramp Automation and Calibration
Category: Laboratory
Product: Titrations
Sub Product: Automatic Titration System
Powerful Customization, Accurate Analysis
The HI901 is an automatic potentiometric titrator that compliments our wide range of products dedicated to quick and accurate laboratory analysis.
This titration system is provided with a host of numerous features suitable for routine sample analysis and performs potentiometric titrations including acid/ base, redox, argentometric and compleximetric. The HI901 can also drive two dosing pumps separately.
This versatile titrator supports up to 100 methods: standard or user defined. When powered on, the instrument initiates an internal diagnostics check and then readies itself for the first titration of the day. A large LCD screen clearly shows the chosen method, correlated information and also indicates which parameters may be adjusted. A real-time titration curve is shown on the display; this feature is useful when developing new methods or when a method needs to be optimized. At the end of the titration, all data, including the graph, are automatically stored in memory and can transferred through direct connection with the supplied serial cable. The titrators are equipped with an RS232 serial port.
Burette maintenance is simple and completely automated. The user can decide to purge or wash the burette, as well as select how many washings to perform. With our exclusive Clip Lock™ system for burette replacement, changing from one titrant to another is done in a flash! Often, preliminary titration operations are very long and arduous. A burette often needs to be adjusted for correct dosing, which extends waiting time for new sample analysis. Hanna has engineered a way to solve this problem.
The innovative Clip-Lock™ system allows users to change burettes in two simple steps, passing from one titrant to the next without any problem. Additionally, HI901 automatically recognizes the volume of the new burette.
Users can connect pH, ORP or ISE electrodes to this unit, as well as create a complete workstation with a PC, monitor, keyboard and printer. This unit complies with GLP specifications, providing validation support for analysis. All GLP information from each sample can be stored, including ID number, date and time of analysis, electrode ID code and last calibration date.
Up to 100 reports of analyses, complete with titration curve graphing are possible. A calibration “time-out” can be set and the user can be advised when the pH electrode needs to be calibrated. The instrument’s status can be viewed clearly on the large LCD screen. Contained in the set-up menu, features like language, display brightness, resolution, pH electrode calibration, date and hour can be adjusted. During analysis, the titration is displayed in real-time together with the stored data. Date, hour, temperature (when probe is connected) and warning messages, such as a pH electrode calibration message are displayed for your convenience.
Read more about Automatic Titration System